Changelog CEMM update 1.10.0

Update 1.10.0 for CEMM has been released. The update will be automatically installed on your CEMM 3.0 during the week of December 16th if automatic updates are enabled. The update can be installed manually immediately.
Still using a CEMM basic or CEMM plus? Take advantage of all the new features by purchasing a one-time upgrade to CEMM 3.0.
Changelog
- Added support for energy monitoring via Shelly smart plugs (Shelly Plug gen1, Shelly Plus Plug S gen2 and Shelly Plug S gen3).
- Added a “meter” to store weather data from openweathermap.org in the CEMM.
- New (temperature and humidity) sensors added to the Teracom module: TSH330, TSM400-4-TH and TSM400-4-CPTH (also air pressure and CO₂).
- New “Current Channel” widget: this shows a current value with a graph of the last 24 hours and the minimum and maximum values in that period below it.
- New "CO₂ Level" widget: This shows the current CO₂ level on a scale from excellent to poor. It also shows the ratio of this scale over the past 24 hours.
- New “Wind” widget: this shows the current wind direction and speed.
- New "Meter" widget: this displays the current value in a small gauge. It can be used to display relative humidity on a scale of 0 to 100%, solar gain, or other measurements on a custom scale.
- New "Value Range Overview" widget: This widget displays the number of days the value fell within each range for four adjustable ranges. This can be set to the number of days in the current month or year. One of its applications is to display days with no, low, moderate, or high gas consumption.
- New “Energy Distribution” widget: this shows the consumption/generation ratio of multiple meters.
- “Welcome widget” can now optionally show statistics.
- The solar panel meter widget (production meters) now shows the current and current balance instead of just the yield (Modbus kWh meters also measure inverter consumption (at night), so this is now offset).
- Added new icons for devices and numbers 0-9.
- It is now possible to adjust the roll of a meter.
- Fixed a bug that prevented the export of meter readings at monthly resolution from working.
- Exporting meter readings now takes meter changes into account. The end time and reading before the change are added to the export.
- Exporting meter readings now uses the last recorded time and reading of the day/month (previously, this was the first recorded value). This means this is the highest meter reading per day/month instead of the lowest (if the meter reading only increases).
- List of paired devices added to the meter settings page.
- Added the option to add an extension to a meter. This was already possible by performing several separate actions, but now it's combined into a single action.
- Fixed a bug that caused rates to not be saved correctly when adding a smart meter.
- CEMM Display will now reload a few minutes after midnight to apply updates and fix any issues
- Some smart meters occasionally fail to include a decimal point in the meter reading, resulting in a reading that is 1000 times too high. The CEMM can now detect this error and ignore the inflated meter reading.
- Fixed a bug that prevented the ability to enable beta updates.
- Lots of small improvements, and bugs fixed.